Created on 06/21/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
MWGM
Vented, balanced, load control valve
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
Vented, balanced load control valves combine a balanced modulating element with a reverse flow check. The check
valve allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating
element controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting. Backpressure at
port 2 does not affect the flow setting because the spring chamber references the vent (port 4).
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at Reseat See Technical Features
Check Cracking Pressure 1,7 bar
Seal kit - Cartridge Buna: 990-023-007
Seal kit - Cartridge Polyurethane: 990-023-002
Seal kit - Cartridge Viton: 990-023-006
(X)CONTROL
X Not Adjustable
(I)MINIMUM CONTROL PRESSURE
I 300 psi (20 bar)
E 75 psi (5 bar)
G 150 psi (10,5 bar)
K 450 psi (33 bar)
M 525 psi (36,7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/
MWGM
TECHNICAL FEATURES
This valve has no relief function. Not even thermal expansion relief.
Maximum valve leakage at reseat for I, K, M ranges is 5 drops/min. (0,3 cc/min.) at 200 psi (14 bar) below cracking pressure; E and G ranges is 3 cubic in/min. (50
cc/min.) at 50 psi (3,5 bar) below cracking pressure; H range is 3 cubic in/min. (50 cc/min.) at 75 psi (5 bar) below cracking pressure.
E, G, H ranges are not meant for zero leak type applications.
This valve is balanced against load pressures and therefore exhibits self-compensation. Flow is controlled by the pilot pressure. Because of dynamic seals,
performance is best in the meter out mode with port 1 being the load and port 2 being tank.
All 4-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
This valve is a physical replacement for a counterbalance valve but probably won't work well in a cross-piloted cylinder application. A low pilot ratio is needed for
machine stability and a balanced load control has an infinitely high pilot ratio.
Applications that use a separate pressure source to the pilot have been successful in providing smooth and stable load control.
Sun load control and counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in
the circuit.
This valve has positive seals between all ports.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
Model Code Example: MWGMXINCONFIGURATION OPTIONS
Created on 06/21/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
PERFORMANCE CURVES